Product Details:
Payment & Shipping Terms:
|
Product Name: | Steam Pressure Tester | Working Pressure: | 0.22 MPa |
---|---|---|---|
Working Temperature: | 134℃ | Heating Equilibrium: | ≤± 2℃ |
Power/Voltage: | 18KW/380V 50Hz | Gross Weight/Net Weight: | 580/470 KG |
Highlight: | temperature humidity test chamber,low temperature refrigerator |
Steam Pressure Tester For Hospital , Pharmaceutical Factory And Scientific etc.
1.Machine summary:
High Pressure Heat Steam Aging Test Chamber is a new type of electromechanical integration equipment.
The mechanical body is a pressure vessel, it is strictly designed and manufactured according to GB150-1998.
All the points which directly contact with sterilized item, are made by high quality stainless steel. Safe
and pollution-free, short sterilizing time, easy operation, powerful function and reliable.
2.Main function:
2.1 The sterilization process can be controlled automatically, no need to supervise, easy to operation.
2.2 With the function of drying, can be used to dry the sterilized items.
2.3 Equipped with automatic safety device for over temperature and overpressure.
2.4 Safety interlock device: if the door not be fasted,will alarm and the steam can not access to inner body. If the pressure of the sterilizing chamber more than 0.027MPa, the door will be interlocked.
2.5 Overpressure protection: When the pressure more than normal working pressure, the safety valve will automatic decompress for protection.
2.6 Low water protection device: When water can not achieve the high water level, machine will not turn on. When water shortage, the machine will automatically power off.
2.7 Over current protection:When current overload, the power circuit breaker will automatically power off.
2.8 The sterilizing chamber is made of high quality stainless steel.
3.Application:
High Pressure Heat Steam Aging Test Chamber is suitable for hospital supply room, operating room,
pharmaceutical factory and scientific research department, etc.
Technical parameter:
1.Product Name | High Pressure Heat Steam Aging Test Chamber |
2.The capacity of sterilizing chamber | 500L (Φ700×1300mm) |
3. Working pressure | 0.22 MPa |
4.Working temperature | 134℃ |
5.Sterilizing temperature range | 40℃ - 134℃ |
6.Sterilizing time range | 0-60 min |
7.Drying time range | 0-60 min |
8.Heating equilibrium | ≤± 2℃ |
9. Power/Voltage | 18KW/380V 50Hz |
10. Dimension | 1800×900×1820 |
11.Package size | 1850×1050×2100 |
12.Gross Weight/Net weight | 580/470 KG |
Contact Person: Ms. Fiona Zhong
Tel: +86 135 3248 7540
Fax: 86-0769-3365-7986