logo
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
VR Show
Dongguan Zhongli Instrument Technology Co., Ltd.
Home News

Demystifying the Water Contact Angle: A Small Droplet, A Vast World

China Dongguan Zhongli Instrument Technology Co., Ltd. certification
China Dongguan Zhongli Instrument Technology Co., Ltd. certification
Exceptional company. 5 STAR!!! Ship rapidly the item and very WELL packed and protected.Very good machinery and very good communication with company. i more than highly recommend using Dongguan Zhongli Instrument.

—— Remy Attalin

The response from the seller was very fast and helpful. Issuing and confirming the PO/PI was done in a single day. The product was shipped the next day after the transaction is confirmed. Couldn't be more satisfied in terms of service provided by the seller. The machine is well packed in wooden case. Everything arrived in good condition. Come with

—— Warunee Nahauythong

I'm Online Chat Now
Company News
Demystifying the Water Contact Angle: A Small Droplet, A Vast World
Latest company news about Demystifying the Water Contact Angle: A Small Droplet, A Vast World

Demystifying the Water Contact Angle: A Small Droplet, A Vast World

 

 

In our daily lives, we often observe scenes like this: dewdrops on lotus leaves are crystal clear, like rolling pearls, while water droplets spread out into a film on a glass surface. Behind this lies a crucial concept in surface science—the Water Contact Angle (WCA). It is not only an intuitive manifestation of the interaction between a liquid and a solid surface but also a core metric for measuring the wettability of a material's surface.

 

What is the Water Contact Angle?

 

The water contact angle, as the name suggests, is the angle at the point where a droplet of liquid (usually water), gas, and solid intersect on a flat, uniform solid surface. It is the angle between the tangent line of the liquid-gas interface and the solid-liquid interface, usually denoted by the Greek letter θ.

 

This simple angle defines whether a material is "hydrophilic" or "hydrophobic":

 

θ < 90°Hydrophilic surface. Water droplets tend to spread out, indicating good wettability with the solid surface. Examples: glass, clean metal surfaces, cotton cloth.

Extremely hydrophilic: θ approaches 0°, the droplet almost completely flattens, forming a thin water film.

θ > 90°: Hydrophobic surface**. Water droplets tend to remain spherical and roll off easily. Examples: lotus leaves, wax paper, raincoat coatings.

Extremely hydrophobic: θ > 150°, often referred to as a Superhydrophobic surface. Water droplets form near-perfect spheres, roll off extremely easily, and pick up dirt from the surface—this is the famous "Lotus Effect."

θ = 180°: A theoretical state of perfect non-wetting, which almost never exists in reality.

 

latest company news about Demystifying the Water Contact Angle: A Small Droplet, A Vast World  0

 

Why is the Contact Angle So Important?

 

The contact angle is far more than a theoretical concept; it plays a vital role in scientific research and industrial applications.

 

1. Surface Cleanliness and Anti-Fouling: Superhydrophobic surfaces (high contact angle) are self-cleaning. As raindrops roll off, they adsorb and carry away dust and contaminants. This principle is applied in building exterior coatings, automotive glass and windows, textiles, and outdoor apparel.

 

2. Coating and Printing Industries: In printing, spraying, and dyeing processes, inks or coatings must wet the substrate well (low contact angle) to ensure coating uniformity and adhesion. Measuring the contact angle helps optimize these processes.

 

3.Microfluidics and Biochips: In micron-scale chip channels, liquid flow is dominated entirely by surface tension. By precisely controlling the contact angle (hydrophilic or hydrophobic) in different regions, scientists can manipulate liquid direction, mixing, and separation like designing electrical circuits.

 

4. Medical and Biomaterials: The surface wettability of medical devices implanted in the human body (e.g., artificial joints, cardiovascular stents) is critical. Hydrophilic surfaces often promote cell adhesion and tissue growth, while certain hydrophobic surfaces may resist protein adsorption and blood clotting.

 

5. New Energy and Semiconductors: In fuel cells, the contact angle on the electrode surface affects water management efficiency. In the lithography process of semiconductor manufacturing, the wettability of the photoresist on the silicon wafer directly impacts pattern precision.

 

latest company news about Demystifying the Water Contact Angle: A Small Droplet, A Vast World  1

 

How is the Contact Angle Measured?

 

The most common and classic measurement method is the Sessile Drop Method.

1. A precision micro-syringe is used to produce a tiny, stable droplet (typically 2-5 microliters) on the sample surface.

2. A Contact Angle Goniometer equipped with a high-resolution camera and light source captures a side image of the droplet.

3. Software analyzes the image, automatically fits a tangent at the solid-liquid-gas triple point, and calculates the angle value.

 

For more accurate and comprehensive information, the Advancing Angle and Receding Angle are sometimes measured. The difference between them is called Contact Angle Hysteresis, which is closely related to surface roughness and chemical heterogeneity.

 

Beyond Water: Broader Applications

Although it's called the "water contact angle," the measured liquid is not limited to water. Depending on the application, various liquids (e.g., oils, blood, electrolytes) can be used to evaluate a surface's wettability to specific liquids. This is equally important for fields like lubricants, cosmetics, and the food industry.

 

latest company news about Demystifying the Water Contact Angle: A Small Droplet, A Vast World  2

Equipment Parameter Details
Overall Equipment Parameters
Model ZL-2823A ZL-2823C ZL-2823B
Type Basic Type Standard Type Scientific research type
Size (L*W*H) 425*150*415mm 560*196*525mm 760*200*640mm
Weight 6KG 11KG 21KG
Power Supply
Voltage 100~240VAC
Power 20W 50W
Frequency 50/60HZ
Sample Platform System
Experiment Platform 120*150mm 120*150mm 160*200mm
Platform Movement Manual Manual (can be upgraded to automatic)
Platform Movement range 60*35*80mm
Maximum sample 180mm×∞×30mm 250×∞×60mm
Platform Tilt ----- Manual tilt platform (optional) Manual tilt platform (optional)
Sample Stage Adjustment

Front and rear adjustment manual, stroke 60mm, accuracy 0.1mm

Left and right adjustment: manual, stroke 35mm, accuracy 0.1mm

Up and down adjustment manual, stroke 80mm, accuracy 0.1mm

Acquisition System
Camera U2.0 U3.0
Lens Type HD microscope lens HD microscope lens High fidelity microscope lens
Lens Magnification 6.5times 8times 10times
Zoom -- -- ±3mm
Maximum Shooting Speed 25 frames/S 50 frames/S More models available
Lens Front And Rear Adjustment 10mm 30mm 30mm
Lens tilt Adjustment -- -- ±10°
Camera System
Largest Image 3000(H)×2000(V) 4000(H)×3000(V) 5000(H)×4000(V)
Maximum frame rate 70fps 120fps (can be upgraded to higher frame rates) 200fps (can be upgraded to higher frame rates)
sensor SONY 1/1.8"
spectrum black color and white color
ROI customize
Show Line Width customize
Exposure Time customize
Power Supply 5 VDC USB interface
Transmission USB3 Vision
Injection System
Drop Sample Manual (can be upgraded to automatic) Manual (can be upgraded to automatic) Automatic aspiration and injection
Wetted Manual Manual Manual (can be upgraded to automatic)
Wet Contact Height Identification Manual Manual Manual
Dropping Accuracy 0.2 μL 0.1μL Upgradeable nanoliter system
Liquid Injection Movement Method Manual Manual Manual (can be upgraded to automatic)
Liquid Injection Movement Stroke 40*10mm 50*50mm 50*50mm
Injection control Manual knob type Manual knob type software digitization
Syringe High precision gas tight syringe
Capacity 1000μl 100μl/500μl/1000μl (500μl standard)
Needle 0.51mm all stainless steel super hydrophobic needle (standard configuration) 0.51mm all stainless steel super hydrophobic needle (standard configuration)
Light Source System
Light Source Square LED Round LED Focus on LED
Wavelength 450-480nm 450-480nm 450-480nm
Light Field 40mm×20mm Φ50mm φ50mm
Light Spot   96 capsules intensive formula
Life 50000Hour 50000Hour 50000Hour
Software
Contact angle range 0~180°
resolution 0.01°
Contact angle measurement method Fully automatic, semi-automatic, manual
Analysis method Stop drip method (2/3 state), bubble capture method, seat drop method
Analytical method Static analysis, liquid increasing and shrinking dynamic analysis, wetting dynamic analysis, real-time analysis, bilateral analysis, advance and retreat angle analysis
Test Methods Circle method, ellipse/oblique ellipse method, differential circle/differential ellipse method, Young-lapalace, width and height method, tangent method, interval method
Surface Free Energy
Test Methods Zisman, OWRK, WU, WU 2, Fowkes, Antonow, Berthelot, EOS, adhesion work, wetting work, spreading coefficient
Data Processing
Output Method Automatically generated, can export/print multiple report formats such as EXCEL, Word, spectra, etc.

 

latest company news about Demystifying the Water Contact Angle: A Small Droplet, A Vast World  3

 

Conclusion

 

A seemingly simple small water droplet, when resting on a material surface, becomes a window for us to insight into microscopic surface properties. The contact angle, a simple yet powerful parameter, connects basic research and cutting-edge technology. From the miraculous "Lotus Effect" in nature to high-tech nanochips, its value is ubiquitous. It profoundly reminds us that many great scientific discoveries often begin with careful observation and deep thought about ordinary phenomena around us.

Pub Time : 2025-08-28 13:34:45 >> News list
Contact Details
Dongguan Zhongli Instrument Technology Co., Ltd.

Contact Person: Ms. Fiona Zhong

Tel: +86 135 3248 7540

Fax: 86-0769-3365-7986

Send your inquiry directly to us (0 / 3000)